--- title: "Object" url: "https://help.maxon.net/c4d/en-us/Content/html/COM_ROCKETLASSO_NEUTRON_ASSET_MODIFIER_TRIM-OUT_MDRHYJ0YNJ6QXC1ULG8T3J.html" section_path: "The Node Editor > The individual Assets > Geo Modifier > Trim Spline Modifier > Object" element_id: "COM_ROCKETLASSO_NEUTRON_ASSET_MODIFIER_TRIM" group_id: "OUT_MDRHYJ0YNJ6QXC1ULG8T3J" description: "These settings define the part of the spline that should remain visible. Start 0% and End 50%, for example, leaves out the back half of the spline in …" --- ## Object ### Mode Parameter ID: `IN_JB4SDQOCONBUFLXKNADV9T` This Node supports two modes for the calculation: - Length: All position specifications and also the specifications for animating the opening position on the spline are made in real dimension values. In this mode, therefore, all functions depend on the length and size of the spline. - Percentage: All position and animation information is expressed as a percentage of the length of the Spline and its segments. In this mode you are, therefore, independent of subsequent changes in the size of the spline, for example. ### Start Parameter ID: `ATTR_6EF8D78186B7484F95E835802E19E7E3` · Range: [0..100%] ### End Parameter ID: `ATTR_187F589B831F4EFF9E38E5ECD868CC63` · Range: [0..100%] These settings define the part of the spline that should remain visible. **Start** 0% and **End** 50%, for example, leaves out the back half of the spline in *Percentage mode*. The **Per Segment option** defines if this reduction should be applied to the entire spline or to each existing spline segment individually. By default, the starting positions for **Start** and **End** are determined by the first and last spline point, respectively, or by the starting point only for closed splines. ### From Start Parameter ID: `IN_MO0RC05KE1YMAMZ1PWXNCS` · Range: [0..+∞m] ### From End Parameter ID: `IN_B8RTDYS6IVCSKVKNGQOIOQ` · Range: [0..+∞m] These settings define the area of the spline that should remain visible. **Start** and **End** can be used in **Length mode** with real distances or Length values to measure the corresponding distances on the spline to define the start and end points. The **Per Segment option** defines whether this reduction is to be applied to the entire spline or to each existing spline segment individually. By default, the starting position for **Start** and **End** is defined by the first and last spline point, respectively, or by the starting point only for closed splines. ### Per Segment Parameter ID: `IN_FARPBVPAOZVJ2G1ZBZDLFO` Here you can select whether all calculations of the Node are based only on the overall spline or whether each spline segment is processed individually (e.g., shortened). ### Invert Parameter ID: `ATTR_A5F8A6D008B3428596580F49EB02219E` Herewith the result of the calculation can be inverted. ![Image: 2023-2_node_trim_spline_02.png](https://help.maxon.net/c4d/en-us/Content/Resources/Images/2023-2_node_trim_spline_02.png)\ On the left is an angular Star spline cut in over the start and end. To the right, the Invert option has been activated. The previously cut part of the spline becomes visible. ### Offset Parameter ID: `ATTR_A8E02B8ADA214D66B0EBE0BFAF94966B` · Range: [-∞..+∞%] ### Offset Parameter ID: `IN_U92OQZJJIP5IO_YE_GGZKP` · Range: [-∞..+∞m] This moves the position along the spline to which **Start** and **End** refer. Depending on the mode, you can use percentage values or normal distance values here. How this affects the result is also determined by the following **Mode setting**, which is only available in **Percentage mode**.\ With **Mode** *Loop*, a gap in the spline defined via **Start** and **End** can be moved freely with the **Offset**. In the *Custom* **Mode**, additional **Start** and **End positions** can be defined along the spline, beyond which no **Offset Shift** is possible. If 0% or 100% are used for **Start** and **End in** the **Custom settings**, an increase of the **Offset value** will not only lead to a shift of the gap in the spline course, but it will also result in a shortening of the spline at its end if values arise**(****End+Offset**) that are above 100%. Since in this mode, for example, **end values** far over 100% can also be used, the **Custom mode** can also act at first like the **Loop mode** until the spline shifted via **Offset** has been shifted accordingly far over the end of the spline. ![Image: 2023-2_node_trim_spline_03.png](https://help.maxon.net/c4d/en-us/Content/Resources/Images/2023-2_node_trim_spline_03.png)\ These image sequences clearly show the difference between the Loop and Custom modes. The upper half shows a spline segment shifted using the Offset value. It is not shortened even when moved beyond the original end of the spline. The lower half of the image shows the same offset shift, this time in Custom mode. By defineing 100% for the end point of the spline, the parts shifted beyond the spline end disappear. ### Rate Parameter ID: `ATTR_536088C548964865B339B1F1FCFD81EF` · Range: [-∞..+∞%] ### Rate Parameter ID: `IN_F8RLLNKZLXXI74MRNS_UOQ` · Range: [-∞..+∞m] This value leads to an automatic increase of the **Offset value** over time. The setting refers to a time span of one second. This means that, for example, a **Rate**of 100% increases the **Offset** by 100% within one second. In **Length mode**, corresponding distance values apply here. ### Limit Parameter ID: `IN_M5ACL38XDXKI9KCL4ZDWE9` This can be used to define which results are produced when the **Offset Function** is used. Note that this setting is only available when using **Percentage mode**: - Loop: Sections shifted beyond the boundaries of the spline by **Offset** or **Rate** are retained and reappear accordingly at the other end of the spline. When using closed splines, for example, openings created in the spline can be moved organically over the entire course of the spline. - Custom: Using custom **Start** and **End** values, a spline range can be defined in which the selected section can be moved freely with **Offset** and **Rate**. Spline ranges that go beyond these limits are deleted. ### Clamp Min Parameter ID: `IN_OVSOECV6FDKRKYUBRGMJTT` · Range: [-∞..+∞%] ### Clamp Max Parameter ID: `IN_CWAEIA05CDYUOIEGMH7TJR` · Range: [-∞..+∞%] These settings are only available in **Custom mode**. These values can be used to define a spline range in which the selected section can be moved freely via **Offset** and **Rate**. Spline ranges that exceed these limits are deleted.